The six-story hotel also houses a one-story conference center at the south end. Shortly after construction, hotel personnel observed leaks at several locations. The original contractor asked SGH to investigate the leaks, develop a repair plan, and oversee repairs.
SGH investigated the reported leakage and collaborated with the contractor to develop a repair plan that could be implemented while the building remained occupied. Highlights of our repair design include the following:
- Installing flashing and interior louver waterproofing without removing the existing windows or louvers
- Installing pan flashing below the curtain wall by lowering the front edge of the sill to create the necessary slope for drainage
- Developing details to integrate the weather barrier between adjacent walls systems
- Adding through-wall flashing at the roof line and where a low roof meets a rising wall
We performed confirmation testing to verify repairs successfully addressed the issues.
Project Summary
Solutions
Repair & Rehabilitation
Services
Building Enclosures
Markets
Commercial
Client(s)
The Weitz Company, LLC
Specialized Capabilities
Condition Assessments | Roofing & Waterproofing
Key team members
Additional Projects
Midwest
801 Grand Avenue
The plaza at 801 Grand Avenue, originally constructed in the 1980s, suffered from water leakage into the underground parking garage, paver movement, and paver deterioration. SGH investigated the causes of leakage and paver deterioration, recommended a remedial program, and designed repairs.
Midwest
200 North LaSalle
The Class A office building is located at 200 North LaSalle Drive in the heart of Chicago’s Loop. The thirty-story tower features a curtain wall facade that maximizes tenant views with floor-to-ceiling glass. SGH performed a critical facade examination in accordance with the city’s Exterior Wall Program.